Information About Boiler Operation

The procedure adopted for raising steam will vary from boiler to boiler and the manufacturers' instructions should always be followed. A number of aspects are common to all boilers and a general procedure might be as follows.

Preparations

The uptakes should be checked to ensure a clear path for the exhaust gases through the boiler; any dampers should be operated and then correctly positioned. All vents, alarm, water and pressure gauge connections should be opened. The superheater circulating valves or drains should be opened to ensure a flow of steam through the superheater. All the other boiler drains and blow-down valves should be checked to ensure that they are closed. 


The boiler should then be filled to slightly below the working level with hot de-aerated water. The various header vents should be closed as water is seen to flow from them. The economiser should be checked to ensure that it is full of water and all air vented off. The operation of the forced draught fan should be checked and where exhaust gas air heaters are fitted they should be bypassed. The fuel oil system should be checked for the correct positioning of valves, etc. The fuel oil should then be circulated and heated.

                    
                   ➤ Details About Feedwater Treatment

Raising steam 

The forced draught fan should be started and air passed through the furnace for several minutes to 'purge' it of any exhaust gas or oil vapours. The air slides (checks) at every register, except the lighting up' burner, should then be closed. The operating burner can now be lit and adjusted to provide a low firing rate with good combustion. The fuel oil pressure and forced draught pressure should be matched to ensure good combustion with a full steady flame. 

The superheater header vents may be closed once steam issues from them. When a drum pressure of about 210kPa (2.1 bar) has been reached the drum air vent may be closed. The boiler must be brought slowly up to working pressure in order to ensure gradual expansion and to avoid overheating the superheater elements and damaging any refractory material. Boiler manufacturers usually provide a steamraising diagram in the form of a graph of drum pressure against hours after flashing up.

Also Read  Types Of Turbine
                   
                 ➤ Steam Turbine And Gearing Definition

                   

The main and auxiliary steam lines should now be warmed through and then the drains closed. In addition the water level gauges should be
blown through and checked for correct reading. When the steam pressure is about 300 kPa (3 bar) below the normal operating value the safety valves should be lifted and released using the easing gear. 

Once at operating pressure the boiler may be put on load and the superheater circulating valves closed. All other vents, drains and bypasses should then be closed. The water level in the boiler should be carefully checked and the automatic water regulating arrangements observed for correct operation.